The HH-0828-1.5 filter is for use on power supplies with power factor correction. This filter is designed to operate with power supplies which must meet conducted emission level "B" of EN55022. This configuration is intended for mounting to a circuit board, however other configurations are available. Our applications department will be happy to help you with your installation requirements. We will either put the filter into another standard enclosure or into a special enclosure to meet your unique requirements.
![]() |
![]() |
Operating Voltage | 115 / 250 VAC |
| Operating Current | 1.5 amperes | |
| Operating Frequency | 50/60 Hz | |
| Operating Temperature | -10 to 50 deg. C | |
| Dielectric Withstanding (Line-Ground) | 1500 VAC
for 1 minute |
|
![]() |
Dielectric Withstanding (Line to Line) | 1500 VDC
for 1 minutes |
| Leakage Current | 1.2 mA @ 250 VAC, 50Hz | |
| Residual Voltage (Max after 5 sec.) | 34 Volts | |
| Agency Approvals | UL, CAS, TUV | |
| Need a variation of the HH-0828-1.5? JMK filter designs
can often be modified to meet our customers needs. Changes in input
and output connection styles and even enclosure dimensions are frequently
possible. If you need a modification of the HH-0828-1.5, E-mail our
Engineering Department and explain
your requirements
Interested in placing an order for an HH-0828-1.5? Simply fill out a Purchase Order. |
||