The 851 series filter is designed for use with main frame computers, memory systems, power controllers and other equipment utilising 3 phase power. This filter is designed for use with a wye configuration, but can be used with a delta power input by connecting to terminals 1, 2, and 3 and leaving the neutral (N) terminal unconnected.
This filter can be utilised to meet FCC, IEC or the new Mil-Std-461D requirements. It is available in current ratings of 15, 25, or 35 amperes.
![]() |
|||||||||
![]() |
|
||||||||
![]() |
Operating Voltage | 250 / 480 VAC |
| Operating Current | 15,25,35 amperes | |
| Operating Frequency | 50/60 Hz | |
| Operating Temperature | -20 to 50 deg. C | |
| Dielectric Withstanding (Line-Ground) | 1500 VAC
for 1 minute |
|
![]() |
Dielectric Withstanding (Line to Line) | 1500 VDC
for 1 minutes |
| Leakage Current | 1.5 mA @ 250 VAC, 50Hz | |
| Residual Voltage (Max after 5 sec.) | 34 Volts | |
| Agency Approvals | UL, CSA, TUV | |
| Need a variation of the 0851 Series Filters? JMK
filter designs can often be modified to meet our customers needs.
Changes in input and output connection styles and even enclosure dimensions
are frequently possible. If you need a modification of the 0851 Series,
E-mail our Engineering Department
and explain your requirements
Interested in placing an order for an 0851 Series Filter? Use our On-Line Purchase Order. |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|